cisco 2600重启问题 急


带ce1板卡的cisco 2600当配置成功后不停的重启,是什么原因?请各位大虾指点一二。

那没配置之前是不是也不停重启呢,应该不会是配置的问题吧。电源不稳定、有没有接地你可以查一下。

报如下信息
00:06:28: %DSX1-3-M32_AR_TIMEOUT: Munich 32 action request timeout: Ctrl = 0x408
30003, Channel = 0
-Process= "Serial Background", ipl= 3, pid= 7
-Traceback= 80195430 80195870 80195988 80197EEC 8018D828 8018D9F8 8018DAB4 8001B
AE0 803E91E4
00:06:28: %DSX1-3-M32_AR_TIMEOUT: Munich 32 action request timeout: Ctrl = 0x408
30003, Channel = 0
-Process= "Serial Background", ipl= 3, pid= 7
-Traceback= 80195430 80195870 80195988 80196A08 80198048 8018D828 8018D9F8 8018D
AB4 8001BAE0 803E91E4
00:06:28: %DSX1-3-NOMEMORY: Unit 4, no memory for Channelized interface.
-Process= "Serial Background", ipl= 3, pid= 7
-Traceback= 8018D844 8018D9F8 8018DAB4 8001BAE0 803E91E4
00:06:29: %DSX1-3-M32_AR_TIMEOUT: Munich 32 action request timeout: Ctrl = 0x408
30003, Channel = 31
-Process= "Serial Background", ipl= 3, pid= 7
-Traceback= 80195430 80195870 80195988 80197EEC 80195CD0 80195D78 8018E640 8018D
930 8018D9F8 8018DAB4 8001BAE0 803E91E400:06:28: %DSX1-3-M32_AR_TIMEOUT: Munich 32 action request timeout: Ctrl = 0x408
30003, Channel = 0
-Process= "Serial Background", ipl= 3, pid= 7
-Traceback= 80195430 80195870 80195988 80197EEC 8018D828 8018D9F8 8018DAB4 8001B
AE0 803E91E4
00:06:28: %DSX1-3-M32_AR_TIMEOUT: Munich 32 action request timeout: Ctrl = 0x408
30003, Channel = 0
-Process= "Serial Background", ipl= 3, pid= 7
-Traceback= 80195430 80195870 80195988 80196A08 80198048 8018D828 8018D9F8 8018D
AB4 8001BAE0 803E91E4
00:06:28: %DSX1-3-NOMEMORY: Unit 4, no memory for Channelized interface.
-Process= "Serial Background", ipl= 3, pid= 7
-Traceback= 8018D844 8018D9F8 8018DAB4 8001BAE0 803E91E4
00:06:29: %DSX1-3-M32_AR_TIMEOUT: Munich 32 action request timeout: Ctrl = 0x408
30003, Channel = 31
-Process= "Serial Background", ipl= 3, pid= 7
-Traceback= 80195430 80195870 80195988 80197EEC 80195CD0 80195D78 8018E640 8018D
930 8018D9F8 8018DAB4 8001BAE0 803E91E4

进入监视模式下 ,看下

Explanation Munich 32 is not responding to an action request.

Recommended Action If this message recurs, copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

背板坏了

上次我也在2600h上遇到同样的问题,将CE1拨下后,再慢慢插进,特别注意CE1上的铜边的接地,多插几次就没有问题了,我想应该就是接触和接地不好引起的